Place of Origin: | China |
Brand Name: | Tianan Electric |
Certification: | ISO9001-2000 CE UL |
Model Number: | LW36-145/3150 |
Minimum Order Quantity: | 10 sets |
---|---|
Price: | Pending |
Packaging Details: | Wooden Case |
Delivery Time: | 40 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 1000 PCS/year |
Operation: | Electric Type | Arc-extinguishing Medium: | SF6 |
---|---|---|---|
Rated Voltage: | 132/145KV | Poles Number: | 3 |
Installation Place: | Outdoor | Function: | Protection, OVP(Overvoltage Protection) |
Rated Operating Sequence: | O-0.3s-Co-180s-Co | Product Name: | Electric SF6 3150A Overvoltage Protection 145KV VCB Circuit Breaker |
High Light: | 3150A VCB circuit breaker,Overvoltage Protection 145KV VCB Circuit Breaker,Electric sf6 vacuum circuit breaker |
Electric SF6 3150A Overvoltage Protection 145KV VCB Circuit Breaker
Overview
LW36-126(145)(W)/T3150-40 self-contained power HV AC sulfur hexafluoride circuit breaker is an outdoor product. It is used in electricity grids with altitudes of no more than 2000m (product designs for 3000m are available), environment temperatures of no less than -30℃ (low-temperature products are suitable for -50℃~+40℃), local pollution classes of no more than Class IV, and maximum voltage of 126/145kV to cut off rated currents, fault currents, or switching lines in order to implement control and protection of electricity systems. It can
also be used as a connection circuit breaker.
Parameters of Electric SF6 3150A Overvoltage Protection 145KV VCB Circuit Breaker
Table 1
No. | Items | Unit | Parameters | |
1 | System nominal voltage | kV | 145 | |
2 | Rated voltage | kV | 132 | |
3 | Rated frequency | Hz | 50 | |
4 | Rated current | A | 3150 | |
5 | Rated short-circuit breaking current | kA | 31.5 | 40 |
6 | Rated short-circuit making current | kA | 80 | 100 |
7 | Rated short time withstand current/time | kA/s | 31.5/4 | 40/3 |
8 | Rated peak withstand current | kA | 80 | 100 |
9 | First-pole-to-clear factor | 1.5 | ||
10 | Lightning impulse withstand voltage | kV | 650 | |
11 | 1min power frequency withstand voltage | kV | 275 | |
12 | Creepage distance fracture/to earth | cm/kV | 250/250 | |
13 | Rated operation order | O-0.3s-CO -180s-CO | ||
14 | Making time | ms | ≤110 | |
15 | Breaking time | ms | ≤65 | |
16 | Closing-opening time | ms | ≤100 | |
17 | Closing non-simultaneity | ms | ≤5 | |
18 | Opening non-simultaneity | ms | ≤3 | |
19 | Fracture no of per pole | piece | 1 | |
20 | Mechanical endurance | time | 6000 | |
21 | SF6 gas pressure Rated value (20ºC) Alarm value The lowest function pressure | MPa MPa MPa | 0.55 0.50 0.45 | 0.60 0.55 0.50 |
22 | SF6 moisture content | ppm(V/V) | ≤150 | |
23 | SF6 yearly air leakage percentage | ≤1% | ||
24 | Per set circuit-breaker SF6 gas charging weight | kg | 9 | 11 |
25 | Gross weight of per set circuit-breaker | kg | 2200 | |
26 | Sub-static pull on wiring longitudinal terminal of circuit-breaker horizontal vertical | N N N | 1250 750 1000 | |
27 | Voltage of auxiliary circuit | V | AC220 | |
28 | Opening-closing coil rated voltage rated current | V A | DC220 or DC110 1.29 | |
29 | Energy Storage motor rated voltage rated power | V W | AC220 or DC 220 700 | |
30 | Energy storage time | s | ≤15 | |
31 | Heater voltage power | V W | AC220 100 | |
32 | Standards | GB1984 |
3.2 Mechanical parameters of circuit breaker
Table 2
No. | Name | Unit | Parameters |
1 | Contact travel of moving-contact | mm | 38~42 |
2 | Main drive lever travel of mechanism | mm | 113~118 |
3 | Distance between opening movable and static contact | mm | 75~80 |
Contact Person: admin
Tel: +8613858385873