Place of Origin: | China |
Brand Name: | Tianan Power |
Certification: | ISO9001,IEC |
Model Number: | SC(B)10 |
Minimum Order Quantity: | 10 unit |
---|---|
Price: | Pending |
Packaging Details: | Wooden Case |
Delivery Time: | 60 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 1000 sets/year |
Product Name: | Cast Resin 10~35 KV Dry Transformers SC(B) Series | Transformer Type: | Cast Resin Dry Type Transformer |
---|---|---|---|
Voltage Grade: | 10kV | Working Condition: | Relative Humidity 100%, Ambient Temperature Not More Than 40℃ |
Maximum Temperature Rising: | 100K Or 500K | Cooling Method: | Air Cooling(AN) Or Fan Cooling(AF) |
High Light: | SCB10 Cast Resin Dry Type Transformer,Cast Resin Dry Type Transformer 10kV,dry type transformer 500K three phase |
Cast Resin 10~35 kV Dry Transformers SC(B) Series
PRODUCT FEATURES of Cast Resin 10~35 kV Dry Transformers SC(B) Series
Adopting advanced technology and international first class manufacturing equipment, SC-series resin casting dry type transformer chooses super quality raw materials, with scientific composition, strictly controlled process and higher inspection standards, so it owns the following advantages:
1. The coils could not absorb moist. The core clamp is coated with special anti-corrosive material. It can work under severe conditions. It is not necessary to do a moist-release-treatment on interval running.
Cast Resin 10~35 kV Dry Transformers SC(B) SeriesTEMPERATURE CONTROLLING SYSTEM
Temperature controlling system consists of temperature controller and PT100 temperature measuring component, which are installed in the hottest point of the coils for realizing the temperature measuring and controlling of transformer. It can switch on/off the cooling fan according to temperature change of coils. While the temperature rises up to a certain value, it will send out an alarm signal. PT100 temperature sensor is a measuring component of temperature controlling system. While temperature changes, the resistor of sensor will follow the changes, then the micro processing system of controller measures temperature of coils according to the change value of resistor. If sensor has wire-breaking trouble , temperature controller will send out fault signals of sensor. Temperature controlling system can directly indicate temperature of three-phase coils of transformer during running and it can realize the connection with computer, to realize collective control. Normally, temperature-controlling system is installed in transformer directly. And it can also be installed in duty office as requested.
Cast Resin 10~35 kV Dry Transformers SC(B) Series STANDARDS
This product adopts standards of GB1094, GB1094.11-2007, GB/T10228-2008 and it satisfies
standards of DIN42523, IEC726. Routine test, type test and special test are all according to standards of GB1094.11-2007, GB/T 10228-2008,and Noise-level test, which is specially arranged as routine test item.
SPECIFICATIONS AND DIMENSIONS OF CAST RESIN 10~35KV DRY TRANSFORMERS SC(B) SERIES
Adopting advanced technology and international first class manufacturing equipment, SC-series resin casting dry type transformer chooses super quality raw materials, with scientific composition, strictly controlled process and higher inspection standards, so it owns the following advantages:
1. The coils could not absorb moist. The core clamp is coated with special anti-corrosive material. It can work under severe conditions. It is not necessary to do a moist-release-treatment on interval running.
Cast Resin 10~35 kV Dry Transformers SC(B) Series TEMPERATURE CONTROLLING SYSTEM
Temperature controlling system consists of temperature controller and PT100 temperature measuring component, which are installed in the hottest point of the coils for realizing the temperature measuring and controlling of transformer. It can switch on/off the cooling fan according to temperature change of coils. While the temperature rises up to a certain value, it will send out an alarm signal. PT100 temperature sensor is a measuring component of temperature controlling system. While temperature changes, the resistor of sensor will follow the changes, then the micro processing system of controller measures temperature of coils according to the change value of resistor. If sensor has wire-breaking trouble , temperature controller will send out fault signals of sensor. Temperature controlling system can directly indicate temperature of three-phase coils of transformer during running and it can realize the connection with computer, to realize collective control. Normally, temperature-controlling system is installed in transformer directly. And it can also be installed in duty office as requested.
STANDARDS
This product adopts standards of GB1094, GB1094.11-2007, GB/T10228-2008 and it satisfies
standards of DIN42523, IEC726. Routine test, type test and special test are all according to standards of GB1094.11-2007, GB/T 10228-2008,and Noise-level test, which is specially arranged as routine test item.
SPECIFICATIONS AND DIMENSIONS OF CAST RESIN 10~35KV DRY TRANSFORMERS SC(B) SERIES
Product name | Cast Resin 10~35 kV Dry Transformers SC(B) Series |
Transformer type | Cast Resin Dry Type Transformer |
Voltage grade | 10kV |
Working condition | relative humidity 100%, ambient temperature not more than 40℃ |
Maximum temperature rising | 100K or 500K |
Cooling method | Air cooling(AN) or fan cooling(AF) |