Place of Origin: | China |
Brand Name: | Tianan Power |
Certification: | ISO9001,IEC |
Model Number: | S9-M |
Minimum Order Quantity: | 10 unit |
---|---|
Price: | Pending |
Packaging Details: | Wooden Case |
Delivery Time: | 60 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 1000 sets/year |
Product Name: | S9 Series 10KV Copper Winding Off-load Tap Changer Transformer | Rated Voltage: | 10KV |
---|---|---|---|
Usage: | High Frequency | Type: | Oil Type |
Cooling Method: | ONAN/ONAF | Winding Material: | Cooper |
High Light: | 35kV 250 kva 3 phase transformer,250kva 3 phase transformer S9 winding,oil power transformer ONAN Cooper |
S9 series 10KV Copper winding off-load tap changer transformer
1. S9 series 10KV Copper winding off-load tap changer transformer General
1.1 Application
10~35kV class transformers are widely used in power transmission and distribution stations, industry plants, Generation Step-up Unit (GSU). They have the characteristic of high efficiency, low loss and maintenance free.
1.2 Type and Rating
Capacity range: 50-50000KVA
Secondary voltage: 415V, 400V etc.
Frequency: 50Hz, 60Hz
Type: Single phase, three phase
No-load tap changer and on-load tap changer
ONAN and ONAF
Set-up and set-down type
1.3 Standard
IEC60076-1, IEC60076-2, IEC60076-5, IEC60317, ANSI, IEEE, AS, etc.
2. Condition of service of S9 series 10KV Copper winding off-load tap changer transformer
2.1.1 Altitude: Up to 1000m above sea level
2.1.2 Ambient temperature:
Max. +40℃
Average (daily, Max.) +30℃
Average (yearly, Max.) +20℃
Min. -45℃
2.1.3 Application: Outdoor
2.2 Special conditions: It may be consulted between manufacturer and customer.
3. Structure feature of S9 series 10KV Copper winding off-load tap changer transformer
3.1 Iron core
The iron core is made of cold rolled grain oriented silicon steel sheet. Laminations are cut to length on GEORG cut-to-length line with step-lap cut and automatic stacking functions. The multi-step lamination structure can reduce the loss and noise. The steel sheet in the core limbs and yokes are clamped together by glass-epoxy bonds.
4. S9 series 10KV Copper winding off-load tap changer transformer Technical data of typical products
Type | Rating kVA | On-load loss(w) | Load loss(w) | I (%) | UK (%) | Dimension(mm) | Weight (kg) | ||
a | b | c | |||||||
S9-M-50/10 | 50 | 170 | 870 | 2.0 | 4.0 | 1215 | 660 | 1170 | 430 |
S9-M-250/10 | 250 | 560 | 3050 | 1.2 | 4.0 | 1190 | 815 | 1370 | 1115 |
S9-M-400/10 | 400 | 800 | 4300 | 1.0 | 4.0 | 1515 | 770 | 1580 | 1380 |
S9-M-500/10 | 500 | 960 | 5050 | 1.0 | 4.0 | 1635 | 840 | 1610 | 1600 |
S9-M-1000/10 | 1000 | 1700 | 10300 | 0.7 | 4.5 | 1960 | 1095 | 1960 | 2860 |
S9-M-2500/10 | 2500 | 3300 | 23000 | 0.55 | 5.5 | 2230 | 2305 | 2445 | 5660 |