Standard: | IEC60076-1, IEC60076-2, IEC60076-5 | Poles Number: | 4 |
---|---|---|---|
Structure: | ACB | Rated Voltage: | 12kv |
Frequency: | 50Hz | Product Name: | 12kv Acb High Voltage Load Switch 100a 4 Pole Load Break Isolator |
Application: | Indoor | ||
High Light: | 12kv high voltage load switch,ACB high voltage load switch,100A 4 pole load break isolator |
12kv ACB High Voltage Load Switch 100A 4 Pole Load Break Isolator
General of 12kv ACB High Voltage Load Switch 100A 4 Pole Load Break Isolator
FN26-12 type SF6 load breaking switch (LBS) is the type with SF6 as the insulating and arc-extinguishing medium which we designed specially for middle voltage grid. This product is successfully developed on the basis of assimilating foreign advanced technology and analysis of power supply status of our country. After type test and long-term operation, it is proved that the product has the following characteristics:
Service condition of 12kV ACB High Voltage Load Switch 100A 4 Pole Load Break Isolator
1. The altitude ≤ 1000m.
2. The ambient air temperature: Highest: +40℃, the lowest:-10℃
3. The relative Humidity of air not bigger 90% (around the 25℃ environment)
4. The working situation should have no conductivity dust, no corrosive gas of affect insulation and destroy metal, no explosive danger and fire, without violent vibration and striking.
Technical parameter of 12kv ACB High Voltage Load Switch 100A 4 Pole Load Break Isolator
No. | Item | unit | Parameter |
1 | Rated Voltage | kV | 12 |
2 | Max. Working Voltage | kV | 12 |
3 | Rated Frequency | Hz | 50 |
4 | Rated Current | A | 100 |
5 | Rated Short-circuit Switch-off Current | kA | 50 |
6 | 1min Power Frequency Withstand voltage(value), to ground, interphase/isolation break | kA | 42/48 |
7 | Lighting Impluse Resisting Voltage (peak) to ground, interphase/isolation break | kV | 75/85 |
8 | Fuse Link Striking Output Energy | Kg | ≈5 |
Technical Parameter of load switch with fuse | |||
No. | Item | Unit | Parameter |
1 | Rated Voltage | kV | 12 |
2 | Max. Working Voltage | kV | 12 |
3 | Rated Frequency | Hz | 50 |
4 | Rated Current | A | 630 |
5 | Rated Power load switch-off current | A | 630 |
6 | 5% rated power load switch-off current | A | 31.5 |
7 | Rated capacity switch-off current | A | 10 |