Place of Origin: | China |
Brand Name: | Tianan Power |
Certification: | ISO9001,IEC |
Model Number: | HXGT6A-24 |
Minimum Order Quantity: | 10 unit |
---|---|
Price: | Pending |
Packaging Details: | Wooden Case |
Delivery Time: | 60 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 100 sets/year |
Product Name: | XGN58 (HXGT6A)-24 Box Type Gas Insulated Metal-clad Switchgear | Type: | Box Type |
---|---|---|---|
Rated Voltage: | 24Kv | Rated Current: | 630A |
Application: | Indoor | Rated Frequency: | 60Hz |
Rated Short Circuit Breaking Current: | 25kA | Applicable Standard: | GB3906, IEC62271-200 |
High Light: | 60Hz medium voltage gas insulated switchgear,XGN58 medium voltage gas insulated switchgear,metal clad switchgear box type |
XGN58 (HXGT6A)-24 box type gas insulated metal-clad switchgear
Overview of XGN58 (HXGT6A)-24 box type gas insulated metal-clad switchgear:
The switchgear is suitable for RMU and double radiation power supply in 12/24kV power supply circuit. The product is especially suitable for industrial and commercial zones or rural area, which have high-density power supply load and use cable feed network. Meanwhile, the RMU has the advantages of safe operation, no weather influence, easy installation, little maintenance and space saving, which is suitable to be installed in box-type substation. The RMU can be flexibly combined by the extension of bus bars.
Service Conditions for XGN58 (HXGT6A)-24 box type gas insulated metal-clad switchgear:
1. Altitude: Not more than 3000m above the sea level;
2. Ambient temperature: Max: +40℃, Min: -40℃;
3. Relative humidity: Daily average is not more than95%, monthly average is not more than 90%;
4. No apparent pollution of corrosive or combustible gas around, seismic intensity is not more than eight class.
5. No regular violent vibration, seismic intensity is not more than eight class;
Note: if deviation of normal service conditions occurs, the customer can negotiate with the manufacturer.
Feature for XGN58 (HXGT6A)-24 box type gas insulated metal-clad switchgear:
Parameter of XGN58 (HXGT6A)-24 box type gas insulated metal-clad switchgear:
No. | Item | unit | Parameter | |||
1 | Rated voltage | KV | 24 | |||
2 | Rated bus bar current | A | 630,1250 | |||
3 | Rated current | A | 630 | |||
4 | Rated frequency 1min | HZ | 50/60 | |||
5 | Rated short-time withstand current | KA | 20/4,25/2 | |||
6 | Rated peak withstand current | KA | 50,63 | |||
7 | Rated short-circuit making current | KA | 50,63 | |||
8 | Rated Current of load switchgear with fuse wire | A | 100 | |||
9 |
Rated short-circuit breaking current
|
fuse | KA | 31.5 | ||
Circuit breaker | KA | 20,25 | ||||
10 | 1min Power frequency withstand voltage |
(phase to phase/ phase-to-ground/chasm)
|
KV | 42/48,65/79 | ||
lightning impulse withstand voltage (peak value) |
(phase to phase/ phase-to-ground) (phase to phase/ phase-to-ground | KV | 75/85,125/145 | |||
Circuit resistance | Load switchgear | μΩ | 130 | |||
Composite apparatus cabinet(not include fuse resistance) | μΩ | 250 | ||||
Circuit breaker cabinet SF6 | μΩ | 140 | ||||
11 | SF6 Rated Gas pressure (20ºC gauge pressure) |
Mpa | 0.04 | |||
12 | SF6 Gas annual Leakage rate | ≤0.2% | ||||
13 | Protection grade (gas filled enclosure) | IP67 |
Contact Person: admin
Tel: +8613858385873