Tel:
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Home ProductsOil Immersed Power Transformer

Off Load Tap Changing 220kV Phase Converter Transformer Off Circuit YNd11 IEC

Off Load Tap Changing 220kV Phase Converter Transformer Off Circuit YNd11 IEC

  • Off Load Tap Changing 220kV Phase Converter Transformer Off Circuit YNd11 IEC
  • Off Load Tap Changing 220kV Phase Converter Transformer Off Circuit YNd11 IEC
Off Load Tap Changing 220kV Phase Converter Transformer Off Circuit YNd11 IEC
Product Details:
Place of Origin: China
Brand Name: Tianan Power
Certification: ISO9001,IEC
Model Number: TA-1547
Payment & Shipping Terms:
Minimum Order Quantity: 10 unit
Price: Pending
Packaging Details: Wooden Case
Delivery Time: 60 work days
Payment Terms: L/C, T/T
Supply Ability: 100 sets/year
Contact Now
Detailed Product Description
Transformer Type: Oil Immersed Power Transformer Frequency Characteristics: High Frequency
Cooling Method: ONAF/ONAN Product Name: 220kV Three-phase Two-winding Off-circuit Tap-changing Power Transformer
Connection: YNd11 Phase Number: 3
High Light:

220kV phase converter transformer Off circuit

,

phase converter transformer YNd11

,

off load tap changing transformer iec

220kV Three-phase Two-winding Off-circuit Tap-changing Power Transformer

 

The 220KV transformer adopted the full folding plate tank structure of 110KV transformer, making its structure more rational, easier for site installation and inspection. Combining our many years of design and manufacture experiences, the reliability and performance of the product have reached international advanced level.

 

Through continuous improvement and alteration, our products are with characteristics of low loss, low noise, low partial discharge, high short circuit withstand capacity, high impedance, and fully-enclosed structure. The series covers two-winding and three-winding off-circuit tap changing power transformer, on-load tap changing transformer and tap-changing auto transformer. Main features as follows:

 

1. 220kV Three-phase Two-winding Off-circuit Tap-changing Power Transformer  Product Features

1.1 Product standards

GB1094.1~2-2013

GB1094.3-2003

GB1094.5-2008

GB/T6451-2008

IEC60076

1.2 Low loss

Optimization of electromagnetic calculations, using combined technology of electrical shielding and magnetic circuit, effectively controlled leakage, s0 as to reduce the load loss and to avoid partial overheating.

1.3 Low partial discharge

To ensure the safe and steady operation of the transformer under continuous rated voltage, our Electric Power Research Institute conducted loads of research to develop a more reasonable insulation structure, plus the strict technology specifications and technical staff experience, ensured the low partial discharge of our products.

1.4 High strength

Adoption of six-side positioning method for the body, meets the transportation requirements of, horizontal acceleration not more than 0.3g, vertical direction not greater than 0.1 5g.

 

2 220kV Three-phase Two-winding Off-circuit Tap-changing Power Transformer Product Features Technology Features

2.1 Transformer oil tank sealed structure adopted Tianan typical design, with strict control of sealing material and the compression coefficient of the sealing rings, a formal leakage test would be carried out after the completion of assembly process, so as to ensure the tank is leakage-free.

2.2 Changed the traditional process of coil assembly. use pre- assembly structural design, with the technology and craft, to avoid decrease of mechanical strength caused by the overall contraction during the drying process.

Use imported laminated wood at coil ends, with good mechanical and electrical quality.

Constant pressure device is used during the transformer assembly process, to apply axial pretightening force on the three-phase coil and insulation parts.

 

3. 220kV Three-phase Two-winding Off-circuit Tap-changing Power Transformer Product Features Parameter sheet

 

Rated Capacity Voltage and tap range Connection No-load loss(kW) Load loss (kW) No-load current (%) Impedance (%)
HV kV LV kV
31500

 

 

 

 

 

 

220±2x2.5%

 

242±2x2.5%

6.3

6.6

10.5

11

 

 

 

 

 

 

 

 

YNd11

35 135 0.70

 

 

 

 

 

 

 

 

12~14

40000 41 157 0.70
50000 49 189 0.65
63000 58 220 0.65
75000

10.5

11

13.8

67 250 0.60
90000 77 288 0.55
120000 94 345 0.55
150000

11

13.8

15.75

18

20

112 405 0.50
160000 117 425 0.49
180000 128 459 0.46
240000 160 567 0.42
300000

 

15.75

18

20

189 675 0.38
360000 217 774 0.38
370000 221 790 0.38
400000 234 837 0.35
420000 242 868 0.35

 

 

 

Off Load Tap Changing 220kV Phase Converter Transformer Off Circuit YNd11 IEC 0

 

 

 

 

 

 

Contact Details
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Contact Person: admin

Tel: +8613858385873

Send your inquiry directly to us
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
21/F, Building 1, No. 816,Jinghua Road, Hi-tech Zone,Ningbo, Zhejiang, P.R. China
Tel:86-574-87911488
Mobile Site Privacy Policy | China Good Quality High Voltage Switchgear Supplier. © 2021 - 2022 voltageswitchgear.com. All Rights Reserved.