Shell Material: | Stainless Steel | Environment: | Outdoor |
---|---|---|---|
Rated Voltage: | 126KV | Poles Number: | Three |
Function: | Circuit-Breaker Failure Protection | Rated Operating Sequence: | O-0.3s-Co-180s-Co |
Rated Short Circuit Duration: | 4s | Product Name: | 3 Pole Vcb 110kv 31.5ka High Voltage Vacuum Circuit Breaker Lw36 |
High Light: | 110kV high voltage vacuum circuit breaker,31.5KA high voltage vacuum circuit breaker,3 pole VCB circuit breaker LW36 |
3 Pole VCB 110kV 31.5KA High Voltage Vacuum Circuit Breaker LW36
General
LW36-126 type outdoor circuit breaker is a high performance new type HV SF6 circuit breaker based on sufficient absorbing and digesting advanced technology of foreign SF6 circuit breaker, and according to the requirement of national standard, combining domestic commercial manufacture level and design.
This product is used in electric system with 50Hz, 110kV system nominal voltage, and which is main electrical equipment controlled and protected by power station and substation. It can be equipped with CT□ type spring operating mechanism and three-phase mechanical linkage. Inside filling SF6 gas having excellent arc extinction and electrical insulation performance. All seals adopt double-circle O type seal ring, which can prevent leakage efficiently.
3 Pole VCB 110kV 31.5KA High Voltage Vacuum Circuit Breaker LW36 feature
a. Excellent breaking performance of arc-extinguish chamber;
b. Reliable spring operating mechanism;
c. Safe and reliable operation;
d. Less maintenance;
e. High insulation level;
f. Good shock resistance and anticorrosion capacity.
Technical Data of 3 Pole VCB 110kV 31.5KA High Voltage Vacuum Circuit Breaker LW36
Name | Unit | Parameter | |
Rated voltage | KV | 126 | |
Rated frequency | Hz | 50 | |
Rated current | A | 3150 | |
Rated short circuit breaking current | KA | 31.5/40 | |
Rated short time withstand current | KA/s | 31.5 (4)/40(3) | |
Rated peak making current | KA | 100 | |
Rated peak withstand current | KA | 100 | |
All breaking time | Ms | < =65 | |
Closing time | Ms | < =110 | |
Breaking factor of first phase | 1.5 | ||
Out -of-phase breaking current | KA | 10 | |
Rated operation sequence | 0-0.3s-CO-180s-CO | ||
Continuous breaking rated short-circuit current endurance | Times | 20 (40kA) | |
Mechanical endurance | Times | 6000 | |
Rated SF6 gas pressure | M pa | 0.55MPa/0.60 | |
Rated power frequency withstand voltage | Phase-to-earth, phase-to-phase | KV | 275 |
Isolating distance | KV | 275 | |
Rated lightning impulse withstand voltage | Phase-to-earth, phase-to-phase | KV | 650 |
Isolating distance | KV | 650 |