Tel:
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Home ProductsMedium Voltage Switchgear

12kv SF6 Medium Voltage Switchgear

12kv SF6 Medium Voltage Switchgear

  • 12kv SF6 Medium Voltage Switchgear
  • 12kv SF6 Medium Voltage Switchgear
12kv SF6 Medium Voltage Switchgear
Product Details:
Place of Origin: China
Brand Name: Tianan Power
Certification: ISO9001,IEC
Model Number: HXGN26-12(F)
Payment & Shipping Terms:
Minimum Order Quantity: 10 unit
Price: Pending
Packaging Details: Wooden Case
Delivery Time: 60 work days
Payment Terms: L/C, T/T
Supply Ability: 100 sets/year
Contact Now
Detailed Product Description
Product Name: HXGN26-12(F) Box Type AC Metal-clad RMU Type Of Current: AC
Rated Voltage: 12kv Application: Indoor
Insulation Medium: SF6 Type: Metal-clad RMU Switchgear
Altitude: ≤1000m Mechanical Life: 10000 Times
High Light:

12kv Medium Voltage Switchgear

,

SF6 gas insulated Medium Voltage Switchgear

,

Indoor medium voltage panel ODM

HXGN26-12(F) Box Type AC Metal-clad RMU

 

This product features small bulk, lightweight, easy operation, safety operation, easy maintenance, etc. It is a newly type of high voltage switchgear suitable for municipal power net improvement and reconstruction.

 

Service condition for HXGN26-12(F) Box Type AC Metal-clad RMU
a. Altitude≤1000m
b. Ambient air temperature: Maximum +40ºC Minimum -35ºC
c. Relative humidity: Diary average value shall be not more than 95%; monthly average value shall be
not more than 90%.
d. Ambient air should be with no corrosion, no apparent pollution with combustible gas and etc.
e. No normal intensive vibration

 

Structure of HXGN26-12(F) Box Type AC Metal-clad RMU:

6.1 RMU is composed of enclosure, load switch, earthing switch, instrument room, busbar, other electric elements and auxiliary elements, load switch is layed on the middle and upper level of the enclosure, the enclosure is composed of bended aluminum zinc alloy coated steel sheet.

6.2 SF6 gas pressure meter is equipped in the face of RMU, so that it can surveil the change of gas pressure in the load switch. Service SF6 rated gas pressure of the product is 0.04MPa (surface Pressure).

6.3 Three phase of RMU is layed in lengthways, three phase busbar connection between the cubicles is very convenient.

6.4 Instrument room is lay in the upper side of RMU, the room can equipped with current meter, pressure meter, switch, indicator light and other elements etc. Secondary circuit terminal also can be equipped in the bottom of the instrument room.

6.5 Cubicles are equipped with lighting device, and lighting switch is installed in the instrument room.

 

Technical parameters of HXGN26-12(F) Box Type AC Metal-clad RMU:

NameUnitParameters
Rated VoltagekV12
Rated FrequencyHz50
Rated Main Busbar CurrentA630
Main Circuit, Earthing Circuit Rated Short-time Withstand CurrentkA/s25/2
Main Circuit, Earthing Circuit Rated Peak Withstand CurrentkA63
Main Circuit ,Earthing Circuit Rated Short-circuit Making CurrentkA63
Full Capacity Breaking Times of Load SwitchTimes100
Fuse Breaking CurrentkA31.5 40
Service LifeTimes10000
1min Power frequency withstand Voltage (r.m.s) Between Phases, to Earth/ Isolation DistancekA42/48
Lightning Impulse Withstand Voltage (Peak) Between Phases, to Earthing/ Isolation DistancekV75/85
Secondary Circuit 1min Power Frequency Withstand VoltagekV2

 

Contact Details
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Contact Person: admin

Tel: +8613858385873

Send your inquiry directly to us
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
21/F, Building 1, No. 816,Jinghua Road, Hi-tech Zone,Ningbo, Zhejiang, P.R. China
Tel:86-574-87911488