Tel:
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Home ProductsMedium Voltage Switchgear

Outdoor Medium Voltage Gas Insulated Switchgear 3150KV XGN75 4000m

Outdoor Medium Voltage Gas Insulated Switchgear 3150KV XGN75 4000m

  • Outdoor Medium Voltage Gas Insulated Switchgear 3150KV XGN75 4000m
  • Outdoor Medium Voltage Gas Insulated Switchgear 3150KV XGN75 4000m
Outdoor Medium Voltage Gas Insulated Switchgear 3150KV XGN75 4000m
Product Details:
Place of Origin: China
Brand Name: Tianan Power
Certification: ISO9001,IEC
Model Number: XGN75-12(Z)
Payment & Shipping Terms:
Minimum Order Quantity: 10 unit
Price: Pending
Packaging Details: Wooden Case
Delivery Time: 60 work days
Payment Terms: L/C, T/T
Supply Ability: 100 sets/year
Contact Now
Detailed Product Description
Product Name: Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z) Rated Voltage: 12KV
Rated Current: 630, 1250, 2000, 2500, 3150KV Rated Frequency: 50Hz
Altitude: ≤4000m Medium Material: SF6 Gas
Application: Indoor Type: Fixed Type And Box Type
High Light:

Gas Insulated Switchgear 3150KV

,

Gas Insulated Switchgear XGN75

,

outdoor medium voltage switchgear 4000m

Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z)

 

General of Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z)

XGN75-12 (Z) Indoor gas insulation metal-clad switchgear is designed and developed by our company self and adopted permanent magnet mechanism vacuum circuit breaker as main switch and HV live conductor is full-enclosed in SF6 room. It is suitable as a new generation metal-clad switchgear automatic-distribution, compact and able to extend.

This switchgear conforms to IEC 62271-200 and all primary components employed therein are in accordance with the relevant standards.

It is designed to accommodate high performance vacuum circuit breaker (VCB) which has been designed and tested in accordance with IEC62271-100.

The switchgear panels are suitable for the assembly of single &double busbar systems for indoor installation.

 

Characteristic of Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z)

1. Reliable
Each compartment is monitored individually &has its own pressure relief device.
Use of Vacuum circuit breakers with high number ofmechanical & electrical operations
Robust interlocking system
2. Safety
The primary side components are hermetically enclosed, gas filled compartment and thus insensitiveto atmosphere, dirt &dust.
Current transformer are mounted outside the gas compartment & mounted on earthed LV compartment
3. Space saving
Smaller foot prints. All operations on the switchgear front
4. Economically efficient
Reduced space & surface area requirement.
Long service life
Maintenance free Gas compartment

 

Technical data of Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z)

S/N Item Unit Data
1 Rated voltage kV 12
2 Rated current A 630 1250 2000 2500 3150
3 Rated frequency Hz 50
4 Rated power frequency withstand voltage (1 min) Phase to phase, phase to earth kV 42
Insulation distance 48
7 Rated lightning impulse withstand voltage Phase to phase, phase to earth kV 75
Insulation distance 85
10 Power frequency withstand voltage of auxiliary
control circuit (1 min)
V 2000
11 Rated short-cricuit breaking current (rms) kA 25 31.5 40
12 Rated short-circuti making current kA 63 80 100
13 Rated short time withstand current kA/s 25/4 31.5/4 40/4
14 Rated peak withstand current kA 63 80 100
15 Degree of protection   Gas-filled compartment : IP67
LV compartment: IP4X
16 Every phase main return circuit resistance <250
17 Rated SF6 gas pressure (20ºC) Mpa 0.045
18 Min SF6 gas pressure (20ºC) Mpa 0.03
19 Annual SF6 gas loss rate % ≤0.5
20 Rated voltage of auxiliary control circuit V DC 110/220
AC 220
21 Dimensions (WxDxH) mm 500x1200x2300

 

Operation procedure of Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z)

Power transmission operation: (circuit breaker is closing and three-position disconnector is earthing):

  1. Operate the circuit breaker to the open position
  2. Operate the three-position disconnector to the disconnected position
  3. Continue to operate the three-position disconnector to the service position
  4. Operate the circuit breaker to the closed position

Power off overhauling operation

  1. Operate the circuit breaker to the closed position
  2. Operate the three-position disconnector to the disconnected position
  3. Continue to operate the three-position disconnector to the earthing position

Measure outlet cable after confirmed it loses electricity and then the circuit breaker could be closed.

 

Outdoor Medium Voltage Gas Insulated Switchgear 3150KV XGN75 4000m 0

Outdoor Medium Voltage Gas Insulated Switchgear 3150KV XGN75 4000m 1

 

Contact Details
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Contact Person: admin

Tel: +8613858385873

Send your inquiry directly to us
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
21/F, Building 1, No. 816,Jinghua Road, Hi-tech Zone,Ningbo, Zhejiang, P.R. China
Tel:86-574-87911488
Mobile Site Privacy Policy | China Good Quality High Voltage Switchgear Supplier. © 2021 - 2022 voltageswitchgear.com. All Rights Reserved.