Product Name: | KYN18A-12 Drawable AC Metal-Clad Switchgear | Rated Voltage: | 12KV |
---|---|---|---|
Rated Frequency: | 50Hz | Degree Of Protection: | IP4X |
Rated Current: | 1250 1600 2000 3150KV | Type: | Draw-out Type |
Application: | Indoor | Rated Lightning Impulse Withstand Voltage (peak): | 75KV |
High Light: | 12kV Medium Voltage Switchgear,KYN18A Medium Voltage Switchgear,125kA switchgear electrical panel Draw out |
KYN18A-12 Drawable AC Metal-Clad Switchgear
General of KYN18A-12 Drawable AC Metal-Clad Switchgear
This Switchgear is available to AC 50Hz, rated voltage of 10kV, single busbar or double busbar power net for power transmission, distribution and measuring. It is mainly used as measuring, protecting and controlling in power transmission and distribution system in power station, substation, seaport, airport, workshops or mines, etc.
It is a metal-clad, mid-mounted and draw-out type of switchgear, and it consists two components, one is main body formed by thin steel plate as a frame structure and another component is a draw-out part (called as truck). Main busbar components, truck component, cable (current transformer) component, relay component, etc. Should be divided by earthing thin steel plate in the switchgear. The truck is a kind of hanging type with advantages of good exchange capacity, flex operation, light weight and easy for maintenance, etc.
Product feature of KYN18A-12 Drawable AC Metal-Clad Switchgear
A. It has package structure and is assembled by nuts with rivet and bolts with high intensity. The enclosure is made of 2.5mm zinc steel sheets coated with aluminum by imported from Switzerland without surface treatment. The material of the door is high quality steel sheets by resin toner electrostatic spraying. It is featured by beautiful looking, resistance to impact surface, anti-corrosion, good antioxidation, high mechanical intensity and easy installation as well as easy maintenance.
B. The steel sheets are bent by imported numerical equipments, which made the body is light than the same kind of equipment, and with good mechanical intensity, high accuracy, easy assembly as well as realizing the unify of the materials.
C. It has middle mounted structure, which enlarge the cable space and makes the height of cable installation to 700mm as well as makes it possible for the switchgear to connect with multiple cables; 6 single core cables at most.
D. Unload the middle clapboard and load and unload clapboard of busbar room, which make such activity occur on the face of the switchgear very convenient, as the connection of main busbar, the installation and examine and repair of cable, earthing switch, lightning arrestor and current transformer etc.
E. Each HV compartment is completely isolated. On each ceiling of them there is a compression release passage, which ensure that the internal arc fault doesn't influence the compartment nearby and the equipments and personnel are safe. All the HV/LV compartments are well sealed. The instrument room is fitted in automatic condensation controller. And the HV compartments are fitted in plate shape heating device to make the surface of the insulator dry inside the switchgear. And the body is fitted in light.
F. The moving contact and static contact of circuit breaker room adopt bridge type multi-point connection type to ensure the safety of contact and large range of temperature rise as well as big creeping insulation piece and large-size cable room and busbar room space, all above make it possible for the switchgear to work on the bad condition.
G. It can be operated while closing. The normal operation of the switchgear must be done under the condition of HV compartment door is closed in order to ensure the safety of the personnel, including opening/closing of circuit breaker, the trolley of circuit breaker is pulled to the working position and exits to testing/ isolating position and the opening/ closing of the earthing switch.
H. Combined truck and insulating structure of body, it makes the interlock safe, reliable and flexible. The trolley has breaking position, testing position and working position inside the switchgear. Each position has orientation device to make sure the reliability of the interlock.
Specification of KYN18A-12 Drawable AC Metal-Clad Switchgear
Rated voltage, kV | 12 |
Rated current, A | 1250 1600 2000 3150 |
Rated frequency, Hz | 50 |
4s Rated peak withstand current | 31.5 40 50(3s) |
Rated peak withstand current (peak), kA | 80 100 125 |
Rated lightning impulse withstand voltage (peak), kV | 75 |
Rated 1min power frequency withstand voltage | 42 |
Degree of protection | IP4X |