Prefabricated 50Hz 132KV Silver Mobile Transformer Substation 2000A

Prefabricated 50Hz 132KV Silver Mobile Transformer Substation 2000A

  • Prefabricated 50Hz 132KV Silver Mobile Transformer Substation 2000A
  • Prefabricated 50Hz 132KV Silver Mobile Transformer Substation 2000A
Prefabricated 50Hz 132KV Silver Mobile Transformer Substation 2000A
Product Details:
Place of Origin: China
Brand Name: Tianan Power
Certification: ISO9001,IEC
Model Number: CZBT1
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: Pending
Packaging Details: PALLET, Nude
Delivery Time: 60 work days
Payment Terms: L/C, T/T
Supply Ability: 100 sets/year
Contact Now
Detailed Product Description
Type: Combined Type Transformer Substation Material: Copper,Steel
Frequency: 50Hz Coil Structure: Toroidal
Product Name: Prefabricated Containerized Power Transformer Mobile Substation Application: Power Conversion & Distribution
Color: Silver
High Light:

50Hz Mobile Transformer Substation

,

132KV Silver Mobile Transformer Substation

,

Prefabricated electrical transformer station 2000A

Prefabricated Containerized Power Transformer Mobile Substation

 

1. General of Prefabricated Containerized Power Transformer Mobile Substation

Tianan developed the prefabricated mobile substation (hereinafter named vehicle-borne substation for short) successfully by itself according to situation of international and domestic, so that fill up the blank in domestic. This substation is mainly used for replacing totally or partially for one regular substation immediately in urgent condition and recover to supply power; it can be put into operation in high load season or time to dissolve the problem of lacking supplied power capacity in one zone; in some zones where the need of electric power is rising and exceed advance electric power construction layout, the substation can be put into operation as temporary substation to dissolve lack of electric power; and also to the zone of breaking off permanent substation construction plan because of fund shortage or other reasons. Vehicle-borne substation features of convenient transport, perfect equipment, agile and reliable, save the found for takeover of land, civil work and installation of equipment at one time and improve the reliability of supplying power in electric power system.

 

2. Technical parameters of Prefabricated Containerized Power Transformer Mobile Substation

 

Rated capacity of main transformer kVA

5000,6300,8000,10000,12500,16000,20000,25000.

Technical parameters of HV side switch equipment

2.1 Rated parameters of disconnector (Table 1)

Table 1

No. Item Unit Parameter
1 System voltage kV 132
2 Rated voltage kV 145
3 Rated frequency Hz 50
4 Rated current A 2000, 1600
5 Rated 1min power frequency withstand voltage kV 275
6 Rated lightning impulse withstand voltage kV 650
7 Rated short time withstand current KA 25, 31.5, 40
8 Rated short time withstand time s 3
9 Rated peak withstand current kA 63, 80, 100

2.2 Rated technical parameter of circuit breaker (Table 2)

Table 2

No. Item Unit Parameter
1 System voltage kV 132
2 Rated voltage kV 145
3 Rated frequency Hz 50
4 Rated current A 2000
5 Rated 1min power frequency withstand voltage kV 275
6 Rated lightning impulse withstand voltage kV 650
7 Rated short time withstand current / time KA/s 40/4
8 Rated peak withstand current kA 100
9 Rated short circuit breaking current kA 40
10 Rated short circuit making current kA 100
11 DC component % 40
12 Rated operation sequence   O 0.3s CO 180s CO
13 Opening time ms 35±5
14 Closing time ms 105±15
15 Breaking time ms ≤60
16 Non-simultaneity between poles Closing ms ≤5
Opening ms ≤3
17 Fracture no. of each pole Quantity 1
18 Mechanical endurance Times ≥6000
19 Full capacity continuous breaking times Times ≥20
20 SF6 gas pressure(20℃) Rated value MPa 0.60
Alarm value MPa 0.55
Locking value MPa 0.50
21 SF6 gas moisture content(μl/l) Acceptance value PPm ≤150
Operation allowable value PPm ≤300
22 SF6 yearly gas leakage rate % ≤0.5
23 Total weight of each circuit breaker kg 2000
           

 

2.3 Parameters of current transformer (Table 3, table 4)

Table 3

Rated primary current 150,300,500,750,1000,1500,2000
Rated secondary current 5A
Rated output capacity and accuracy level See table 4

 

Table 4

Current ratio Rated output capacity VA Measure accuracy level Protection accuracy level

150/5

300/5

500/5

750/5

1000/5

1500/5

2000/5

20

20

30

30,40

40,50

50

50

0.5

0.5

0.5

0.5

0.5

0.5

0.5

5P20

5P20

5P20

5P20

5P20

5P20

5P20

Note: (1) Straight-through type bushing current transformer is attached in the circuit breaker.

 

3. Parameters of lightning arrester(Table 5), parameters of neutral point lightning arrester(Table 6).

Table 5

No. Item Unit Parameter
1 System voltage kV 132
2 Rated voltage kV 150
3 Rated frequency Hz 50
4 Nominal discharge current kA 10
5 DC 1mA reference voltage kV ≥245
6 Residual voltage under lightning impulse current (peak) kV ≤435
7 Residual voltage under operation impulse current (peak) kV ≤370
22 Residual voltage under steep wave impulse current (peak) kV ≤490

Table 6

No. Item Unit Parameter
1 System voltage kV 132
2 Rated voltage kV 90
3 Rated frequency Hz 50
4 Nominal discharge current kA 1.5
5 DC 1mA reference voltage kV ≥140
6 Residual voltage under lightning impulse current (peak) kV ≤260
7 Residual voltage under operation impulse current (peak) kV ≤240
8 Residual voltage under steep wave impulse current (peak) kV /

4.Technical parameters of switch equipment on LV side(Table 7)

Table 7

No. Item Unit Parameter
1 System voltage kV 11.5
2 Rated voltage kV 12
3 Rated frequency Hz 50
4 Rated current A 2000,1600,1250,
5 Rated 1min power frequency withstand voltage kV 42/48
6 Rated lightning impulse withstand voltage kV 75/85
7 Rated short time withstand current kA 40,31.5,25
8 Rated short time withstand time s 4
9 Rated peak withstand current kA 100,80,63
10 Rated short circuit breaking current kA 40,31.5,25
11 Rated short circuit making current kA 100,80,63
12 Rated operation sequence   O 0.3s CO 180s CO
13 Mechanical endurance Times ≥10000

5. Sound level of the substation:≤65 Db

6. Protection grade of enclosure of switch chamber:IP23(when the door for natural ventilation is open); IP43(when the door for natural ventilation is closed).

 

7.Prefabricated Containerized Power Transformer Mobile Substation Typical scheme 

25MVA

Prefabricated 50Hz 132KV Silver Mobile Transformer Substation 2000A 0

 

40MVA

 

Prefabricated 50Hz 132KV Silver Mobile Transformer Substation 2000A 1

 

Contact Details
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Contact Person: admin

Tel: +8613858385873

Send your inquiry directly to us
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
21/F, Building 1, No. 816,Jinghua Road, Hi-tech Zone,Ningbo, Zhejiang, P.R. China
Tel:86-574-87911488
Mobile Site Privacy Policy | China Good Quality High Voltage Switchgear Supplier. © 2021 - 2022 voltageswitchgear.com. All Rights Reserved.