Place of Origin: | China |
Brand Name: | Tianan Power |
Certification: | ISO9001,IEC |
Model Number: | HXGT6B-12F-T630-20 |
Minimum Order Quantity: | 10 unit |
---|---|
Price: | Pending |
Packaging Details: | Wooden Case |
Delivery Time: | 60 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 100 sets/year |
Product Name: | Power Distribution Cabinet, 12KV Medium Voltage Gas-insulated Switchgear, Indoor | Application: | Indoor |
---|---|---|---|
Rate Voltage: | 12kV | Rated Current: | 630A |
1min Power Frequency Withstand Voltage: | 42kV | Rated Lighting Impulse Withstand Voltage: | 75kV |
Protection Degree Of Enclosure: | IP4X | Rated Gas Pressure: | 0.03MPa |
High Light: | 630A general electric medium voltage switchgear,42kV general electric medium voltage switchgear,Intelligent switchgear organization 0.03MPA |
Power distribution Cabinet, 12KV Medium Voltage Gas-insulated Switchgear, Indoor
HXGT6B-12F-T630-20 series RMU switchgear is new environmentally-friendly type applied in city grid transformation and construction. It can also be fit for combined power station as side HV equipment of the station.
Technical Parameters of HV Fuse
Type | XRNT-12 | XRNT-24 |
Rated Voltage | 12 | 24 |
Rated Fuse Current | 100 | |
Rated Fusant Current | 10/16/20/31.5/40/50/63/80/100 | |
Rated Breaking Current | 31.5 |
Electrical parameters of load switch, load switch-fuse composite apparatus and circuit breaker
Item | Unit | Parameters | |||||
Unit | Load Switch | Composite apparatus | Circuit breaker | ||||
1 | Rated Voltage | kV | 12,24 | ||||
2 | Rated Frequency | Hz | 50/60 | ||||
3 | Rated Current | A | 630 | 100 | 1250 | ||
4 | Rated Short-time Withstand Current | kA/s | 20/4,25/2 | 20/4,25/2 | |||
5 | Rated Short Circuit Making Current (Peak) | kA | 50 | 50,63 | |||
6 | Mechanical Life | Times | 5000 | 5000 | 10000 | ||
7 | 1min Power Frequency Withstand Voltage to Earth, Between Phases/ Across the open gap | kV | 42/48,65/79 | ||||
8 | Lightning Impulse Withstand Voltage to Earth, Between Phases/ Across the open gap | kV | 75/85,125/145 | ||||
9 |
Rated single capacitor bank/ back to back capacitor bank breaking current |
A | 630/400 | ||||
10 | Motor Operational Power Supply, Voltage | V | DC48, AC220, 110 | ||||
11 | Rated Short circuit breaking current | A | 31.5 | 20 ,25 | |||
12 | Rated Transfer Current | A | 1500 | ||||
Ordering notice for Power distribution Cabinet, 12KV Medium Voltage Gas-insulated Switchgear, Indoor:
Contact Person: admin
Tel: +8613858385873