Place of Origin: | CHINA |
Brand Name: | Tianan Electric |
Certification: | XIHARI |
Model Number: | GW |
Minimum Order Quantity: | 1 unit |
---|---|
Price: | Pending |
Packaging Details: | Standard export package |
Delivery Time: | 45 days |
Payment Terms: | L/C, T/T |
Supply Ability: | 100 units / year |
Voltage: | 72.5kV ~ 420kV | Current: | 1250A ~ 5000A |
---|---|---|---|
Frequency: | 50/60Hz | Motor Voltage: | AC380/DC220 |
Phase: | Single-Stage | Run: | Turn The Horizontal |
Product Name: | HV Disconnect Switch Break Isolator Double Side 3 Phase Disconnect | Structure Of Operating: | Manual |
High Light: | 420kV HV Disconnect Switch,5000A HV Disconnect Switch Double Side,break isolator 3 phase disconnect |
S/N | Item | Unit | Parameter | ||||
1 | Rated voltage | kV | 72.5 | 145 | 252 | 363 | 420 |
2 | Rated insulation level | ||||||
3 | Rated power frequency withstand voltage (1 min) | ||||||
4 | To earth | kV | 160 | 275 | 460 | 210 | 520 |
5 | Across open breaks | kV | 200 | 275+85 | 460+145 | 210+210 | 610 |
6 | Rated lightning impulse withstand voltage | ||||||
7 | To earth | kV | 350 | 650 | 1050 | 1175 | 1425 |
8 | Across open breaks | kV | 410 | 650+120 | 1050+200 | 1175+295 | 1425+240 |
9 | Rated switch impulse withstand voltage (peak) | ||||||
10 | between phase/ to earth | kV | -- | -- | -- | 1425/950 | 1574/1050 |
11 | Across open breaks | kV | -- | -- | -- | 850+295 | 900+345 |
12 | Rated frequency | Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
13 | Rated current | A | 1250 2000 2500 3150 4000 | 1250/2000 | 2000 2500 3150 4000 5000 | 31,50 | 3150 |
14 | Rated short-time withstand current | kA | 40 50 | 31.5/40 | 50/63 | 160 | 160 |
15 | Rated peak withstand current | kA | 100 125 | 80/100 | 125/160 | 63 | 63 |
16 | Rated duration of short circuit | s | 4 | 4 | 3 | 3 | 2 |
17 | Rated terminal mechanical load | ||||||
18 | Horizontal -logntitudinal | N | 750/1000 | 1250 | 1500 | 2500 | 2000 |
19 | Horizontal- vertical | N | 500/750 | 750 | 1000 | 2000 | 660 |
20 | Vertical force | N | 750 | 1000 | 1250 | 1500 | 1500 |
21 | Isolating switch bus capacity of switching currents and opening/ closing | 100V, 1600A, 100 times | 100V, 1600A, 100 times | 300V, 1600A, 100 times | 450V, 3200A, 3times 400V, 1600A, 100 times | 300V, 1600A, 100 times | |
22 | Grounding switch induction current open/ closing capacity | ||||||
23 | Electromagnetic induction-typ current (current/ voltage) | A/kV | 100/4 (80/2) | 100/6 (80/2) | 160/15 (80/3) | 1250/35 (160/10) | 160/10 (80/2) |
24 | electrostatic induction current (current/ voltage) | A/kV | 2/6 | 5/6 (2/6) | 10/15 (3/12) | 50/50 (18/17) | 18/20 (1.25/5) |
25 | Times of opening and closing | times | 10 | 10 | 10 | 10 | 10 |
26 | isolating switch small current open/ closing capacity | ||||||
27 | capacitive current | A | -- | 1 | 1 | 1 | 1 |
28 | Inductive current | A | -- | 0.5 | 0.5 | 0.5 | 0.5 |
29 | RIV radio interference voltage | uV | <500 | <500 | <500 | <500 | <500 |
30 | Creepage distance | mm | >1813 2248 | >3625 4495 | >6300 7812 | >9450 | >10500 |
31 | Mechnical endurance | times | 5000 | 5000 | 1000 | 5000 | 10000 |
32 | Applicable altitudes | <2000 | <2000 | <2000 | <3000 | <1000 | |
33 | Motor operating mechanism | ||||||
34 | Model | CJ2 | CJ2 | SRCJ2 | SRCJ2 | SRCJ2 | |
35 | Motor voltage | V | AC 380 DC220 | AC 380 DC220 | AC 380 DC220 | AC 380 DC220 | AC 380 DC220 |
36 | Control circuit's voltage | V | AC 220 DC220 DC110 | AC 220 DC220 DC110 | AC 220 DC220 DC110 | AC 220 DC220 DC110 | AC 220 DC220 DC110 |
37 | Opening time and closing time | s | 7+1 | 7+1 | 16+1 | 16+1 | 16+1 |
38 | Output shaft rotation | 180 | 180 | 180 | 180 | 180 | |
39 | Manual operating mechanism | ||||||
40 | Model | CS11 | CS11 | SRCS | SRCS | SRCS | |
41 | control circuit voltage | V | AC 220 | AC 220 | AC 220 | AC 220 | AC 220 |
Structure and working principle of 420kV 5000A HV Disconnect Switch Break Isolator Double Side 3 Phase Disconnect
Earth switch(see the right picture),the movement is by CJ -3 institutions operating lever to earth switch through a link after the conversion, driving a four-link active grounding arm rotation, due to the active arm and door type bracket and earthing pipe is composed according to the design requirements special four-link system, thus ensuring the earth switch in the closing process, the first rotary motion, near the closing position, linear motion upward, insert static inner contact, opening and vice versa.
Contact Person: admin
Tel: +8613858385873