Product Details:
Place of Origin: CHINA
Brand Name: Tianan Electric
Certification: XIHARI
Model Number: GW
Payment & Shipping Terms:
Minimum Order Quantity: 1 unit
Price: Pending
Packaging Details: Standard export package
Delivery Time: 45 days
Payment Terms: L/C, T/T
Supply Ability: 100 units / year
Contact Now
Detailed Product Description
Voltage: 72.5kV ~ 420kV Current: 1250A ~ 5000A
Frequency: 50/60Hz Motor Voltage: AC380/DC220
Phase: Single-Stage Run: Turn The Horizontal
Product Name: HV Disconnect Switch Break Isolator Double Side 3 Phase Disconnect Structure Of Operating: Manual
High Light:

420kV HV Disconnect Switch

,

5000A HV Disconnect Switch Double Side

,

break isolator 3 phase disconnect

420kV 5000A HV Disconnect Switch Break Isolator Double Side 3 Phase Disconnect
 
420kV 5000A HV Disconnect Switch Break Isolator Double Side 3 Phase Disconnect Description
GW7 series Isolator switch(disconnectors) are outdoor 3-phase high voltage equipment. They are used to change over power circuit and electrically isolate the repaired equipment under no-load condition. GW7 are type of 3 poles centre rotating and double horizontal breaks.
 
420kV 5000A HV Disconnect Switch Break Isolator Double Side 3 Phase Disconnect Technical data
S/NItemUnitParameter
1Rated voltagekV72.5145252363420
2Rated insulation level      
3Rated power frequency withstand voltage (1 min)      
4To earthkV160275460210520
5Across open breakskV200275+85460+145210+210610
6Rated lightning impulse withstand voltage      
7To earthkV350650105011751425
8Across open breakskV410650+1201050+2001175+2951425+240
9Rated switch impulse withstand voltage (peak)      
10between phase/ to earthkV------1425/9501574/1050
11Across open breakskV------850+295900+345
12Rated frequencyHz50/6050/6050/6050/6050/60
13Rated currentA1250
2000
2500
3150
4000
1250/20002000
2500
3150
4000
5000

31,50
5,000

3150
14Rated short-time withstand currentkA
40
50
31.5/4050/63160160
15Rated peak withstand currentkA
100
125
80/100125/1606363
16Rated duration of short circuits44332
17Rated terminal mechanical load      
18Horizontal -logntitudinalN750/10001250150025002000
19Horizontal- verticalN500/75075010002000660
20Vertical forceN7501000125015001500
21Isolating switch bus capacity of switching
currents and opening/ closing
 100V, 1600A,
100 times
100V, 1600A,
100 times
300V, 1600A,
100 times

450V, 3200A, 3times
400V, 1600A,
100 times
300V, 1600A,
100 times
22Grounding switch induction current open/ closing capacity     
23Electromagnetic induction-typ current (current/ voltage)A/kV100/4 (80/2)100/6 (80/2)160/15 (80/3)1250/35 (160/10)160/10 (80/2)
24electrostatic induction current (current/ voltage)A/kV2/65/6 (2/6)10/15 (3/12)50/50 (18/17)18/20 (1.25/5)
25Times of opening and closingtimes1010101010
26isolating switch small current open/ closing capacity     
27capacitive currentA--1111
28Inductive currentA--0.50.50.50.5
29RIV radio interference voltageuV<500<500<500<500<500
30Creepage distancemm>1813
2248
>3625
4495
>6300
7812
>9450>10500
31Mechnical endurancetimes500050001000500010000
32Applicable altitudes <2000<2000<2000<3000<1000
33Motor operating mechanism      
34Model CJ2CJ2SRCJ2SRCJ2SRCJ2
35Motor voltageVAC 380
DC220
AC 380
DC220
AC 380
DC220
AC 380
DC220
AC 380
DC220
36Control circuit's voltageV
AC 220
DC220
DC110

AC 220
DC220
DC110

AC 220
DC220
DC110

AC 220
DC220
DC110

AC 220
DC220
DC110
37Opening time and closing times7+17+116+116+116+1
38Output shaft rotation 180180180180180
39Manual operating mechanism      
40Model CS11CS11SRCSSRCSSRCS
41control circuit voltageVAC 220AC 220AC 220AC 220AC 220

 
 
Structure and working principle of 420kV 5000A HV Disconnect Switch Break Isolator Double Side 3 Phase Disconnect
Earth switch(see the right picture),the movement is by CJ -3 institutions operating lever to earth switch through a link after the conversion, driving a four-link active grounding arm rotation, due to the active arm and door type bracket and earthing pipe is composed according to the design requirements special four-link system, thus ensuring the earth switch in the closing process, the first rotary motion, near the closing position, linear motion upward, insert static inner contact, opening and vice versa.
 
420kV 5000A HV Disconnect Switch Break Isolator Double Side 3 Phase Disconnect 0

Contact Details
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Contact Person: admin

Tel: +8613858385873

Send your inquiry directly to us
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
21/F, Building 1, No. 816,Jinghua Road, Hi-tech Zone,Ningbo, Zhejiang, P.R. China
Tel:86-574-87911488
Mobile Site Privacy Policy | China Good Quality High Voltage Switchgear Supplier. © 2021 - 2022 voltageswitchgear.com. All Rights Reserved.