Tel:
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Home ProductsHV Disconnect Switch

DC 252kv 125KA HV Disconnect Switch Loop Overheating Loop Overheating

DC 252kv 125KA HV Disconnect Switch Loop Overheating Loop Overheating

  • DC 252kv 125KA HV Disconnect Switch Loop Overheating Loop Overheating
DC 252kv 125KA HV Disconnect Switch Loop Overheating Loop Overheating
Product Details:
Place of Origin: Ningbo,China
Brand Name: Tianan Electric
Certification: ISO9001,IEC
Model Number: GW23 (GT9)
Payment & Shipping Terms:
Minimum Order Quantity: 1sets
Price: Pending
Packaging Details: International package
Delivery Time: 30 days
Payment Terms: T/T, L/C, D/A, D/P
Supply Ability: 5000 setss per year
Contact Now
Detailed Product Description
Rated Voltage: 252kv 363kv Rated Current: 2500A
Withstand Current(peak): 125KA Service Condition: Outdoor
Type: High-voltage Product Name: DC 252kv 125KA HV Disconnect Switch Loop Overheating Loop Overheating
High Light:

252kv HV Disconnect Switch 125KA

,

125KA HV Disconnect Switch

,

DC disconnect switch loop overheating

DC 252kv 125KA HV Disconnect Switch Loop Overheating Loop Overheating

 

General overview

GW23 (GT9) 252D/2500-50 Type Double Column Outdoor AC HV Disconnector is developed on the basis of aiming at existing defects about disconnector conducting loop overheating, operating mechanism failure, metal material corrosion serious, and then making great improvement.

 

DC 252kv 125KA HV Disconnect Switch Loop Overheating Loop Overheating Characteristic:
1. Application of friction type contacting structure in main knife moving conductive contact surface
2. Auto-locking device of breaking and closing positions effectively prevents the separation of dynamic/static contacts due to wind or electric motive force
3. The application of non-oil bearing and copper alloy sleeve on rotating point making it have auto-lubrication function and conquers the corrosion and seizure of the rotating point
4. Application of advanced surface processing technique and anti-rust aluminum, stainless steel greatly enhances surface anti-rust property
5. Three-pole linkage and electric/manual operation of main switch
6. Fitted with earthing switch that has the same short-circuit current withstand capability as disconnector
7. Effective prevention of mal-operation by electric/mechanical dual interlock between disconnector and earthing switch

 

DC 252kv 125KA HV Disconnect Switch Loop Overheating Loop Overheating Technical parameters

 

S/N Name Unit Parameters
1 Rated voltage kV 252
2 Rated current A 2500
3 Peak withstand current of disconnector and earthing switch (peak) kA 125
4 3s short-time withstand current of disconnector and earthing switch (r.m.s) kA 50
5 Main circuit resistance of disconnector μΩ ≤130
6 1min power frequency withstand voltage(r.m.s) Phase-to earth(dry, wet) kV 395
Fracture 460
7 Lightning impulse withstand voltage (1.2/50μs) Phase-to earth kV 950
Fracture 1050
8 Mechanical endurance test of disconnector and earthing switch Times 2000 for each

 

DC 252kv 125KA HV Disconnect Switch Loop Overheating Loop Overheating 0

Contact Details
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Contact Person: admin

Tel: +8613858385873

Send your inquiry directly to us
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
21/F, Building 1, No. 816,Jinghua Road, Hi-tech Zone,Ningbo, Zhejiang, P.R. China
Tel:86-574-87911488
Mobile Site Privacy Policy | China Good Quality High Voltage Switchgear Supplier. © 2021 - 2022 voltageswitchgear.com. All Rights Reserved.