Power Distribution SF6 High Voltage Switchboard Ring Main XGN65

Power Distribution SF6 High Voltage Switchboard Ring Main XGN65

  • Power Distribution SF6 High Voltage Switchboard Ring Main XGN65
  • Power Distribution SF6 High Voltage Switchboard Ring Main XGN65
Power Distribution SF6 High Voltage Switchboard Ring Main XGN65
Product Details:
Place of Origin: China
Brand Name: Tianan Power
Certification: ISO9001,IEC
Model Number: XGN65 (HXGT10)-40.5
Payment & Shipping Terms:
Minimum Order Quantity: 10 unit
Price: Pending
Packaging Details: Wooden Case
Delivery Time: 60 work days
Payment Terms: L/C, T/T
Supply Ability: 100 sets/year
Contact Now
Detailed Product Description
Altitude: ≤2000m Rated Voltage: 40.5KV
Insulation Medium: SF6 Application: Indoor
Type: Distribution Equipment Typical Products: High Voltage
Product Name: 40.5 Type SF6 Ring Main Unit Usage: Power Distribution
High Light:

SF6 high voltage switchboard

,

50Hz high voltage switchboard Ring Main

,

power distribution switchgear XGN65

Hight voltage Switch cabinet XGN65 (HXGT10)-40.5 type SF6 Ring Main Unit

 

Main purpose and application range of XGN65 (HXGT10)-40.5 type SF6 Ring Main Unit

XGN65(HXGT10)-40.5 type SF6 Ring Main Unit(bellow short for Ring MainUnit), is 50Hz AC three phase indoor HV distribution equipment. Load switchgear,earth contact and busbar for circuit are sealed in metal enclosure. It is a composite apparatus which adopt spring operation device and use SF6 as distinguished arc and insulating medium. It is suitable for 40.5 kV power supply and ring power supply and double radiated power supply, which can change the previous ways of one-way radiated power supply. When circuit broke out fault, loss current for transformer

circuit can recover in time, so it can improve reliability and frequency of power supply especial for commerce zone or countryside area. Meanwhile, ring main unit is convenient to use, not easy to influenced by weather, easily equipment, free maintenance, small volume, so it can applicable for box type transformer substation, load –breaking switch of ring main unit or switch-fuse composite apparatus by separate.

 

Type designation of XGN65 (HXGT10)-40.5 type SF6 Ring Main Unit

Power Distribution SF6 High Voltage Switchboard Ring Main XGN65 0

 

Installation and commissioning of XGN65 (HXGT10)-40.5 type SF6 Ring Main Unit

  • User should inspect package complete, cubicle knocked after disassembling, terminal damaged or not when receive goods. Please feel freeto contact manufacturer if you find any problems.
  • This product every parameter is full-sealed, adjusted and tested to be eligible before leaving factory. User does not need to adjust, but need to observe the press meter whether indicating at the scope of rated working and the mechanical motion in normally condition.
  • Cable wiring should be firm, reliable, operated professional.
  • Cubicle body should be firmly fastened with good earthing device.
  • Incoming and outgoing lead out through cable terminal, if aerial outgoing and incoming, it need to lead aerial circuit through cable.

 

XGN65 (HXGT10)-40.5 type SF6 Ring Main Unit Operating procedure 

1. Closing operation for RMU switch

Closing operating hole is open left and insert the grip into it. Spring should be rotary in clockwise to storage energy according to indicating direction. Load switch is closed when the crank past the middle position, it can also be electric closing with press-button. After closing, it should pull out grip and close valve. Indicating plate should be changed into closing position, also lock the earthing switch operating valve, can not operate earthing switch.

2. Open operating of load switch

When the rotary button is screwed as indicating direction, load switch will be closed. It can also be electric close with button. After it is closed, change the place of indicating plate instead of closing. The lock to the earthing switch operating hole valve is released.

3. Closing operating for earthing switch

When operating valve of earthing switch is open right, operating grip should be inserted into operating hole of earthing switch as indicating turn in clockwise. The spring past at the middle of position, release energy, earthing switch close (earthing),pull out grip and close the valve, indicating plate changed into earthing, load switch do not operate.

4. Opening operation of earthing switch

Valve for earthing switch operating hole is pull out right. Operating grip should be inserted into earthing switch operative hole and turn (clockwise) according to indicating direction. Earthing switch is on manually, indicating plate is changed into opening position. Valve for load switch closing operating hole is released.

Altitude ≤2000m
Rated voltage 40.5KV
Insulation medium SF6
Application Indoor
Type distribution equipment
Typical Products High voltage
Product name 40.5 type SF6 Ring Main Unit
Usage Power Distribution

 

Contact Details
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Contact Person: admin

Tel: +8613858385873

Send your inquiry directly to us
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
21/F, Building 1, No. 816,Jinghua Road, Hi-tech Zone,Ningbo, Zhejiang, P.R. China
Tel:86-574-87911488
Mobile Site Privacy Policy | China Good Quality High Voltage Switchgear Supplier. © 2021 - 2022 voltageswitchgear.com. All Rights Reserved.