Application: | Indoor | Usage: | Mobile Switching Station |
---|---|---|---|
Shell Material: | Aluminum Alloy | Operation Voltage: | High Voltage |
Application Range: | Power Plants | Specification: | IEC60076-1, IEC60076-2, IEC60076-5 |
Product Type: | High Voltage Switchgear | Product Name: | Indoor Gas Insulation Metal-Clad Switchgear |
High Light: | 24KV High Voltage Switchgear,High Voltage Switchgear Indoor IEC 60076,gas insulated switchgear 4000 amp |
Indoor Gas Insulation Metal-Clad Switchgear / Air Insulated Switch Cabinet
Overview of Indoor Gas Insulation Metal-Clad Switchgear
These switchgears play an important role in the reconstruction of 110kV substation and guarantee the power supply service during the substation reconstruction, make the power supply during transmission with load successful, and they are under steady operation now.
The 35kV mobile switching station used for transmission with load of 35kV system reconstruction of 110kV Xibao substation is manufactured by your company, equipped with 6 sets of 35kV GIS with type of XGN49-40.5. This switchgear features the advantages of small volume, free maintenance, reliable quality, beautiful appearance, easy installation and use as well as fast after-sales service, Ningbo Tianan is the partner with good reputation and good technical strength.
Main parameters of Indoor Gas Insulation Metal-Clad Switchgear
Item | Unit | Data | ||||
Rated voltage | kv | 3.6, 7.2, 12,24KV | ||||
Rated frequency | hz | 50 | ||||
Rated current of circuit breaker | A | 630, 1250, 1600, 2000, 2500, 3150, 4000 | ||||
Rated current of switchgear | A | 630, 1250, 1600, 2000, 2500, 3150, 4000 | ||||
Rated short-time withstands current(4s) | ka | 16, 20, 25, 31.5, 40, 50 | ||||
Rated peak withstands current (peak value) | ka | 40, 50, 63, 80, 100, 25 | ||||
Rated short-circuit breaking current | ka | 16, 20, 25, 31.5, 40, 50 | ||||
rated short-circuit making current (peak value) | ka | 40, 50, 63, 80, 100, 25 | ||||
Rated insulation level | 1min power frequency withstands voltage | pole to pole, pole to ground | kv | 24, 32, 42 | ||
fracture to fracture | kv | 24, 32, 48 | ||||
lightning withstands voltage(peak) | pole to pole, pole to ground | kv | 40, 60, 75 | |||
fracture to fracture | kv | 46, 70, 85 | ||||
Protection degree | Enclosure is IP4X. IP2X when CPT and CB door are open | |||||
Note: 1. The short-circuit capacity of current transformer is considered separately. 2. Details of the parameters of ZN 63A-12 as per reference company' s sample. |
||||||