Tel:
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Home ProductsHigh Voltage Switchgear

KYN10 1000m High Voltage Switchgear 11kv Gis Switchgear IP4X Metal Enclosed

KYN10 1000m High Voltage Switchgear 11kv Gis Switchgear IP4X Metal Enclosed

  • KYN10 1000m High Voltage Switchgear 11kv Gis Switchgear IP4X Metal Enclosed
  • KYN10 1000m High Voltage Switchgear 11kv Gis Switchgear IP4X Metal Enclosed
KYN10 1000m High Voltage Switchgear 11kv Gis Switchgear IP4X Metal Enclosed
Product Details:
Place of Origin: China
Brand Name: Tianan Power
Certification: ISO9001,IEC
Model Number: KYN10-40.5
Payment & Shipping Terms:
Minimum Order Quantity: 10 unit
Price: Pending
Packaging Details: Wooden Case
Delivery Time: 60 work days
Payment Terms: L/C, T/T
Supply Ability: 100 sets/year
Contact Now
Detailed Product Description
Altitude: Not Exceed 1000m Application: Indoor
Dimension: 1400 (W) X 2200 (D) X 2625 (H) Degree Of Protection: IP4X
Weight (Circuit Cabinet): ≤2500 Circuit Breaker Equipped: ZN12-40.5, ZN23, FP Series, ZN23 Series
Product Name: KYN10-40.5 Draw-out Type AC Metal-clad Switchgear Usage: Power Distribution
High Light:

KYN10 High Voltage Switchgear

,

1000m High Voltage Switchgear

,

11kv gis switchgear IP4X metal enclosed

Description:

KYN10-40.5 series AC metal-enclosed switchgear is the latest self-designed and developed version of switchgear absorbing and digesting advanced technology in domestic and abroad for satisfying domestic specifications. Its technical performances can meet the standards of IEC298and GB3906<3~35kV AC metal-enclosed switchgear>. It has advantage of a smaller volume, a big breaking short-circuit current, easier installation, a long-free-maintenance duration, easier operation and maintenance, safe operation, etc.

 

Use

KYN10-40.5 AC metal-enclosed switchgear is a kind of complete indoor type with three-phase, 50Hz, AC meta-clad truck cubicle. It is used for controlling,receiving and distribution in single busbar and single busbar branch power system of rated voltage 35kV.

 

 

Type designation

KYN10 1000m High Voltage Switchgear 11kv Gis Switchgear IP4X Metal Enclosed 0

 

 

 

 

Service condition

1. Ambient air temperature: -15°C~+40°C.
2. Altitude: ≤1000m.
3. Relative humidity : Daily average≤95%, daily averange of vapour pressure≤2.2kpa.
4. Earthquake intensity: ≤magnitude 8.
5. Applicable in the places without corrosive and flammable gas and water vapor.
6. Used in place without frequently intense vibrant.
Note: Customized products are available.

 

Technical data of KYN10-40.5 switchgear

 

No. Item Unit Data
1 Rated voltage kV 40.5
2 Rated current A 1250,1600,2000
3 Rated short-circuit breaking current kA 25,31.5
4 Rated short-circuit making current (peak) kA 63,80
5 4s rated short-circuit withstand current (virtual value) kA 25,31.5
6 Rated short-circuit withstand current (peak) kA 63,80
7 Fitted breaker  

a. ZN23-40.5 vacuum circuit breaker

b. LN2-40.5 SF6 circuit breaker

c. FP SF6 circuit breaker

d. ZN12-40.5 vacuum circuit breaker

e. 3AH series Siemens vacuum circuit breaker

8 Fitted operating device   CT19 CD10III (ZN23-40.5 vacuum circuit breaker)
9 Dimension(width×depth×height) mm 1400×2200×2625
10 Protection degree IP2X IP4X(consolidation type)

 

 

 

 

Technical data of ZN23-40.5 indoor HV vacuum circuit breaker

No. Item Unit Data
1 Rated voltage kV 40.5
2 Rated current A 1250,1600,2000
3 Rated short-circuit breaking current kA 25,31.5
4 Rated short-circuit making current (peak) kA 63,80
5 4s rated short-circuit withstand current (virtual value) kA 25,31.5
6 Rated short-circuit withstand current (peak) kA 63,80
7 Opening time ms ≤60
8 Closing time ms ≤100
9 Operation sequence   O-0.3s-CO-180s-CO

 

Main technical data of ZN12-40.5 indoor HV vacuum circuit breaker

Item Unit Data
Rated voltage kV 40.5
Rated insulated level 1min power frequency withstand voltage (virtual value) kV 95
Lighting impulse withstand voltage (peak) kV 185
Rated frequency Hz 50
Rated current A 1250,1600,2000
Rated short-circuit breaking current kA 25 31.5
Rated short-circuit withstand current (peak) kA 63 80
4s rated short-circuit withstand current (virtual value) kA 25 31.5
Rated short-circuit making current kA 63 80
Closing time ms ≤90
Opening time ms ≤70
Rated operation sequence O-0.3s-CO-180s-CO
Stored energy generator power W 275
Rated voltage of stored energy generator V ≈110,220
Stored energy time s ≤15
Closing winding voltage V ≈110,220
Opening winding voltage V ≈110,220
Rated short-circuit breaking time Times 20
Rated current breaking time Times 10000
Mechanical endurance Times 10000
Rated current of over-current release A 5
Rated current of auxiliary switch A AC10,DC5
Contact point quantity of auxiliary switch   11groups opening,11groups closing
Contact closing tripping time ms ≤2
Contact opening un-simultaneity ms ≤2
Type of operation device   Integrative spring operation device should be installed with opening & closing button, opening & closing indicator and counter or anti-tripping device


 

Technical data of CT19BN spring operation device

 

No. Item Unit Data
1 Rated voltage of stored energy generator V ~110,220;-110, 220
2 Input power of stored energy generator W 220
3 Stored energy time s ≤14
4 Rated voltage of closing electric magnetic V ~110,220;-110, 220
5 Rated voltage of opening electric magnetic V ~110,220;-110, 220
6 Rated current of over-current release A 5
7 Rated current of auxiliary switch A 10(AC220V), 5(DC220V)
8 Let-through sustained current of travel switch A 10(AC220V), 5(DC220V)
 

 

Technical data of JN12-40.5 earthing switch

No. Item Unit Data
1 Rated voltage kA 40.5
2 4s thermal stability current(virtual value) kA 25
3 Rated dynamic stability current(peak value) kA 63
4 Rated short-time making current(peak time) kA 63

 

Technical data of LDJ1-35 current transformer

Rated primary current: 5~1600A

Rated secondary current: 5A.

Secondary exact class combination: 0.2,0.5,10P.

10P exact limited value factor and secondary load relation curved line, please see the following figure.

 

Technical data of JDZ9-35 and JDX9-35 voltage transformer

Type Voltage ratio(kV) Classes combination Rated outgoing (VA) Limited outgoing (VA)
0.2 0.5 1.0 6P
JDZ9-35 35/0.1/0.1 0.2/0.5 30 50 - - 400
35/0.1 0.2 or 0.5 60 120 - - 800
JDZX9-35 35/√3/0.1√3/0.1√3/0.1/3

 

 

0. 2/0.5/6P

10 30 - 100 300

 

Technical data of YH5WZ-51/134 zinc oxide lighting arrester

Lighting arrester rated voltage System nominal voltage Lighting arrester continuous- running voltage Not less than 1mA DC reference voltage Not more than residual voltage under lighting impulse current 2ms square wave discharge current capacity
kV (virtual value) kV kV (peak) A
51 35 40.8 73 134 150

 

Contact Details
Ningbo Tian'an Jinghua Power Technology Co., Ltd.

Contact Person: admin

Tel: +8613858385873

Send your inquiry directly to us
Ningbo Tian'an Jinghua Power Technology Co., Ltd.
21/F, Building 1, No. 816,Jinghua Road, Hi-tech Zone,Ningbo, Zhejiang, P.R. China
Tel:86-574-87911488
Mobile Site Privacy Policy | China Good Quality High Voltage Switchgear Supplier. © 2021 - 2022 voltageswitchgear.com. All Rights Reserved.