Place of Origin: | China |
Brand Name: | Tianan Power |
Certification: | ISO9001,IEC |
Model Number: | XGN49-40.5/T2500 |
Minimum Order Quantity: | 10 unit |
---|---|
Price: | Pending |
Packaging Details: | Wooden Case |
Delivery Time: | 60 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 100 sets/year |
Rated Current: | 2500A | Rated Voltage: | 40.5KV |
---|---|---|---|
Shell Material: | Aluminum Alloy | Application: | Indoor |
Current: | AC | Installation: | Fixed Type |
Product Name: | XGN49 SF6 Indoor High Voltage Switchgear | Standard: | IEC Standard |
High Light: | XGN49 power distribution cabinet,2500A power distribution cabinet,40.5KV metal clad switchgear Indoor |
XGN49 SF6 Indoor High Voltage Switchgear – 2500A Gas Insulated Switchgear
Product Description of XGN49 SF6 Indoor High Voltage Switchgear
The gas insulated switchgear designed for installation in transformer substation, industrial plants, and infrastructure & complies the most stringent requirement of
Safety in operation
Staff safety Operation reliability
Smaller footprints
Reduced maintenance work
This switchgear conforms to IEC 62271-200 and all primary components employed therein are in accordance with the relevant standards.
It is designed to accommodate high performance vacuum circuit breaker (VCB) which has been designed and tested in accordance with IEC62271-100.
The switchgear panels are suitable for the assembly of single &double busbar systems for indoor installation.
Type designation
XGN49 SF6 Indoor High Voltage Switchgear Features:
1. The introduction of advanced technology in Japan, Toshiba Co., Ltd. to develop products.
2. Good insulation performance, small size, filled with SF6 gas as insulation medium.
3. The reliability of the breaking performance, the vacuum circuit breaker for arc extinction, the life of spring operating mechanism is long.
4. High reliability, the sealed body, and performance that is not affected by the outside world.
5. Safe structure design, all kinds of independent pressure release device, which can be guaranteed from the internal failure.
6. “five-prevention” equipment is reliable, and with mechanical and electrical interlock.
7. The cabinets is connected by external solid insulated busbar, it’s easy for installation.
8. Cable room has enough space for installation.
Data:
Rated voltage | 40.5kV |
Rated frequency | 50,60Hz |
Rated current | 2500A |
Rated short circuit breaking current | 25, 31.5,40kA |
Rated making current | 50, 63, 80kA |
I min power frequency withstand voltage | 95kV ( phase to phase, phase to earth) |
118kV (betwwen isolating clearnace) | |
Rated lightning impulse withstand voltage | 185kV ( phase to phase, phase to earth) |
215kV (betwwen isolating clearnace) | |
Degree of protection | IP67( gas-filled compartment) IP4X (LV compartment) |
Dimension:
Eexternal dimensions for inner cone cable outgoing, Side extension bus , rated current: 2500A,
A. Circuit breaker chamber B. Disconnector bus chamber C. LV chamber
D. Cable chamber E. Gas release channel F. Gas release channel (optional)
Contact Person: admin
Tel: +8613858385873